Install Responsibilities
This page outlines the primary responsibility clients and SyncTimes have for typical installs.
Last updated
This page outlines the primary responsibility clients and SyncTimes have for typical installs.
Last updated
SyncTimes will Provide | Client Responsible to Provide (Typically through subcontractors) |
Firewall () - 1U per site | Network connectivity () |
Switching Equipment () - 1U per 20 rooms | UPS (switches require approx. 400W per 20 rooms) |
Exam room tablets | Low-voltage (CAT5e or better) cabling from clinical areas to wiring closet, punched down into patch panel at closet & RJ45 at rooms |
Ceiling nodes | and |
All patch cables | 120V wiring & outlets (350W per television display) |
PoE Flowstation control module | 19" rack space for SyncTimes network equipment and patch panels (typically 2U per 10 rooms) |
All mounting hardware for tablets | Procurement, install and mounting of Flowstation displays |
Patch panels and rack space for SyncTimes drops |
Clients typically choose to subcontract much of their portion, including low-voltage wiring, 120V wiring, and providing patch panels. All linked products are provided as examples. SyncTimes and clients may use similar hardware provided by other vendors.